59185 A 08.17INSTALLATION GUIDEUS CADOUBLE DISHDRAWERTM DISHWASHERDD24DDFT & DD24DV2T models
9(x2)8 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITAB
10213(x2)!0-A SECURE TO THE CABINETRY ON THE SIDES!2-A AFTER SECURING, REFER TO ‘FIT THE SUPPLIED TOEKICK PANEL’ STEP!1-A OPTIONALLY SECURE TO T
11(x2)1244338 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVALAs you push product in, pull through hoses and cord, ensuring they don’t get kinked or
12x4(x2)1234!0-B SECURE TO THE CABINETRY ON THE SIDES !1-B OPTIONALLY SECURE TO THE CABINETRY ABOVESecure using two pairs of formed brackets. Repe
13!3 FIT THE SUPPLIED TOEKICK PANEL1913578926419IMPORTANT!Do not overtighten screw.Where the toekick meets the bottom of the tub is the cut-off pointM
1412!4 THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.DRAINAGE OPTION 1Dishwasher and Ø 1 1/2” (38 mm) Standpi
15min. R 8” (200 mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 2Dishwasher using Air Break wit
16123min. R 8” (200 mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 3Dishwasher using drain hose
17Ensure the supplied rubber washer is fitted inside the coupling.Tighten coupling with spanner.180oNo leaks!12!7 TROUBLESHOOTING ●Excessive water rem
18!8 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLERComplete and keep for safe reference:Model Serial No. Purchase Date Purchaser Dealer Address I
1IMPORTANT! SAVE THESE INSTRUCTIONSThe models shown in this installation guide may not be available in all markets and are subject to change at any
59185 A 08.17INSTALLATION GUIDEUS CASINGLE DISHDRAWERTM DISHWASHERDD24SDFT & DD24SV2T models
1IMPORTANT! SAVE THESE INSTRUCTIONSThe models shown in this installation guide may not be available in all markets and are subject to change at any
22 PARTS SUPPLIEDClamp (1)(for securing Drain hose joiner)Wire clip (1) (for securing Drain hose joiner)Phillips 5/8” (16mm) screws (7)1 1/2” (38mm)
32133 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION3-A REMOVE THE DRAWER 3-B REMOVE THE ACCESS COVER & REMOVE POWER Access coverClipClipElect
43 OPTIONALLY HARD WIRING PRIOR TO INSTALLATIONIMPORTANT!Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics
54 PRODUCT DIMENSIONSHIFGCABDOEPLANPROFILEFRONTDD24SDFT DD24SV2TPRODUCT DIMENSIONS INCHES (MM) INCHES (MM)AOverall height of product 117 7/8” (4
65 CABINETRY DIMENSIONSMinimum clearances from adjacent cabinetryBracket slotsRQKPROFILEPLANDD24SDFT DD24SV2TCABINETRY DIMENSIONS INCHES (MM) IN
76 CAVITY PREPARATIONWater ConnectionRecommended HOT (Maximum 140°F/60°C).Supplied hose to suit 3/8” (9 mm) male Water Pressure Water softener modelsM
87 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE8 ATTACH CAVITY BRACKET (DD24SDFT MODELS ONLY)LEFT HAND SIDE RIGHT HAND SIDEIMPORTANT! The en
99 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE F
22 PARTS SUPPLIEDIf the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which wi
10213!1-A SECURE TO THE CABINETRY ON THE SIDESOpen the drawer halfway.Using a flat bladedscrewdriver, prise the grey rubber plug out of the trim mou
1121344339 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY !0-B REMOVE THE LOWER DRAWERTo preve
121212344” (100mm)!2-B REFIT THE DRAWER ONTO THE RUNNERS!1-B SECURE TO THE CABINETRY ON THE SIDESBefore refitting the drawer, ensure the hoses are
1312!3 THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.DRAINAGE OPTION 1Dishwasher and Ø 1 1/2” (38 mm) Standpi
1412min. R 8” (200mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 2Dishwasher using Air Break wi
15312min. R 8” (200mm)IMPORTANT!Ensure that drain connection will comply with local plumbing regulations.DRAINAGE OPTION 3Dishwasher using drain hose
16Ensure the supplied rubber washer is fitted inside the coupling.Tighten coupling with spanner.180oNo leaks!12!4 CONNECT INLET HOSE TO HOT WATER !5
17!6 TROUBLESHOOTING ●Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How
18!7 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLERComplete and keep for safe reference:Model Serial No. Purchase Date Purchaser Dealer Address I
19
33 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION3-A REMOVE THE LOWER DRAWER 3-B REMOVE THE ACCESS COVER & REMOVE POWER Access coverClipClipEl
20
43 OPTIONALLY HARD WIRING PRIOR TO INSTALLATIONIMPORTANT!Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics
54 PRODUCT DIMENSIONSBDOENFACMLGJIHKPLANPROFILEFRONTHandles may varyDD24DDFT DD24DV2TPRODUCT DIMENSIONS INCHES (MM) INCHES (MM)AOverall height o
65 CABINETRY DIMENSIONSMinimum clearances from adjacent cabinetryBracket slotsRQPSTPROFILEPLANDD24DDFTDD24DV2TCABINETRY DIMENSIONS INCHES (MM) I
76 CAVITY PREPARATIONWater ConnectionRecommended HOT(Maximum 140°F/60°C).Supplied hose tosuit 3⁄8” (9 mm) malecompression fitting.Kosher requirementsD
87 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGELEFT HAND SIDE RIGHT HAND SIDEDrain hoses - 78 1/2” (2000mm)Drain hoses - 70 1/2” (1800mm)Inl